Teledyne Microwave Solutions


Traveling wave tubes remain the best source for efficient generation of microwave power over broad frequency bandwidths. Pick from the three TWT selection tabs shown below to find a model to match your requirements.

Use the Search area to type in the model or parameter needed, and the corresponding TWT models will be shown. To view the data sheet, just click on the model number in the left column. 

Communication TWTs

Click below
for pdf
Frequency
(GHz)
Power (W) Duty (%) Max. Typical Gain (dB) Min/Max @ Rated Pout Efficiency (%) Typical Modulation (Control Electrode) Output Connection Weight (lbs/kg) (NTE)
MEC 5417 5.85 - 6.45 282** 100 39/41 19 GRID WRD 580 8.5/3.9
MEC 5337 C/Ku 350/400 100 38/52 27 GRID WRD 580 8.5/3.9
MTG 5336B C/Ku 325/325 100 38/52 27 FE WRD 580 8.5/3.9
MTG 5336AX C/Ku 400/400 100 38/52 30 FE WRD 580 8.5/3.9
MTG 5333 C/X/Ku 325/400/325 100 37/46/48 27 GRID WRD 580 8.5/3.9
MTG 5336 C/X/Ku 325/400/325 100 37/46/48 27 FE WRD 580 8.5/3.9
MEC 5599 C/X/Ku 112/158/91 100 41/41/40 28 FE WRD 580 4.5/2.0
MTG 5338X C/X/Ku 350/600/350 100 37/46/48 35* FE WRD 580 8.5/3.9
MEC 5450X 7.9-8.4 600 100 46 35 FE CMR 112 8.5/3.9
MEC 5499/A 13.75 - 14.5 200 100 53/55 32** FE WR 75 8.5/3.9
MEC 5517 13.75 - 14.5 295 100 48/50 34 FE WR 75 4.5/2.0
MEC 5516 X and Ku 125 100 51/53 24 FE WRDG 650 5.5/2.5
MEC 5441 Ku/DBS 350/300 100 43/51 29* GRID WR 62 7.5/3.4
MEC 5442 Ku/DBS 350/300 100 43/51 29* FE WR 62 7.5/3.4
MEC 5452 13.75 - 14.5 500 100 60 40 FE WR 75 8.5/3.9
MEC 5455 13.75 - 14.5 500 100 60 40 GRID WR 75 8.5/3.9
MEC 5466 17.3 - 18.4 450/500 100 45/47 32* FE WR 62 9.0/4.1
MEC 5530L 27.0 - 30.0 250 100 37/40 25 FE WR 28 7.0/3.2
MEC 5530H 30.0 - 31.0 250 100 36/37 25 FE WR 28 7.0/3.2
MEC 5523 43.5 - 45.5 125 100 30/33 23 FE WR 22 7.0/3.2

*OVER MAJORITY OF FREQUENCY RANGE - PERFORMANCE MAY BE REDUCED AT BAND EDGES.

Specifications Subject To Change Without Notice
Teledyne MEC TWTs are controlled by the International Traffic in Arms Regulations, and can only be exported via a U.S. Department of State export license. A few model numbers, as so identified, require a U.S. Department of Commerce Export License. They may not be transferred, transshipped on a non-continuous voyage, or otherwise be disposed of in any other country, either in their original form or after being incorporated into other end-items, without the prior written approval of the U.S. Department of State.

 
Teledyne Microwave Solutions  |  11361 Sunrise Park Drive, Rancho Cordova, CA 95742

Phone: (800) 832-6869  |  © 2018 Teledyne Microwave Solutions. All rights reserved.

 Legal Notices & Terms and Conditions